DocumentCode
2655872
Title
Temperature sensitive paint (TSP) for heat transfer measurement in short duration wind tunnels
Author
Mosharov, Vladimir ; Orlov, Anatoly ; Radchenko, Vladimir
Author_Institution
Central Aero-Hydrodynamic Inst., Zhukovsky, Russia
fYear
2003
fDate
25-29 Aug. 2003
Firstpage
351
Lastpage
356
Abstract
This paper presents an application of temperature sensitive paint (TSP) technique to measure full-field surface heat transfer rates in short-duration wind tunnel. Tests were performed on blunt-nose cone model (nose radius 10 mm, cone half-angle 10°) in shock wind tunnel UT-1 (TsAGI) operated on Ludwig scheme at Mach number M=6 with flow duration 40 msec. Reynolds numbers calculated by nose radius were ranged between 60000 and 210000. Two type of TSP were used: monochromatic and two-color. Two-color paint contains additional temperature insensitive dye to compensate excitation light intensity variation. Experimental results have shown good repeatability but heat flux on the model nose was lower than CFD prediction and thermocouple measurement.
Keywords
Mach number; compressible flow; dyes; flow measurement; heat transfer; paints; temperature measurement; wind tunnels; 40 ms; Ludwig scheme; Mach number; Reynolds numbers; blunt nose cone model; heat flux; heat transfer measurement; light intensity variation; monochromatic colour; shock wind tunnels; short-duration wind tunnel; surface heat transfer rates; temperature insensitive dye; temperature sensitive paint; two-color paint; Calibration; Electric shock; Heat transfer; Luminescence; Nose; Paints; Phosphors; Temperature distribution; Temperature sensors; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Instrumentation in Aerospace Simulation Facilities, 2003. ICIASF '03. 20th International Congress on
Print_ISBN
0-7803-8149-1
Type
conf
DOI
10.1109/ICIASF.2003.1274886
Filename
1274886
Link To Document