DocumentCode :
2656235
Title :
High peak power test of S-band waveguide switches
Author :
Nassiri, A. ; Grelick, A. ; Kustom, R.L. ; White, M.
Author_Institution :
Adv. Photon Source, Argonne Nat. Lab., IL, USA
Volume :
3
fYear :
1997
fDate :
12-16 May 1997
Firstpage :
3174
Abstract :
The injector and source of particles for the Advanced Photon Source (APS) is a 2856-MHz S-band electron-positron linear accelerator (linac) which produces electrons with energies up to 650 MeV or positrons with energies up to 450 MeV. To improve the linac RF system availability, an additional modulator-klystron subsystem is being constructed to provide a switchable hot spare unit for each of the five existing S-band transmitters. The switching of the transmitters will require the use of SF6-pressurized waveguide switches at a peak operating power of 35 MW. A test stand was set up at the Stanford Linear Accelerator Center (SLAC) Klystron-Microwave laboratory to conduct tests characterizing the power handling capability of these waveguide switches. Test results are presented
Keywords :
X-ray production; accelerator RF systems; electron accelerators; electron sources; klystrons; linear accelerators; particle beam injection; storage rings; 2856 MHz; 35 MW; APS; Advanced Photon Source; S-band electron+positron linear accelerator; S-band waveguide switches; electron source; high peak power test; injector; linac RF system availability; modulator-klystron subsystem; power handling capability; pressurized waveguide switches; switchable hot spare unit; Klystrons; Linear accelerators; Linear particle accelerator; Positrons; Power system reliability; Storage rings; Sulfur hexafluoride; Switches; Testing; Transmitters;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1997. Proceedings of the 1997
Conference_Location :
Vancouver, BC
Print_ISBN :
0-7803-4376-X
Type :
conf
DOI :
10.1109/PAC.1997.753146
Filename :
753146