• DocumentCode
    2656691
  • Title

    Analysis and measurements of eddy current effects of a beam tube in a pulsed magnet

  • Author

    Fang, S. ; Chou, W.

  • Author_Institution
    Fermi Nat. Accel. Lab., Batavia, IL, USA
  • Volume
    3
  • fYear
    1997
  • fDate
    12-16 May 1997
  • Firstpage
    3251
  • Abstract
    The power supply design of the γt-jump system in FNAL Main Injector uses a resonant circuit. A critical design parameter is the AC losses of the beam tube in a pulsed quadrupole. This paper gives an analysis to this problem. An equivalent circuit model based on the impedance measurement was established. The measured and calculated losses are in agreement. Another effect of the eddy current is the distortion of the magnetic field inside the beam tube. A Morgan coil was used for field measurements up to 10 KHz. These results are presented in this paper
  • Keywords
    accelerator magnets; booster injectors; equivalent circuits; proton accelerators; pulsed power supplies; synchrotrons; AC losses; FNAL Main Injector; Morgan coil; eddy current effects; equivalent circuit model; impedance measurement; magnetic field; pulsed magnet; pulsed quadrupole; resonant circuit; Current measurement; Distortion measurement; Eddy currents; Equivalent circuits; Magnetic analysis; Magnetic field measurement; Power supplies; Power system modeling; Pulsed power supplies; RLC circuits;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1997. Proceedings of the 1997
  • Conference_Location
    Vancouver, BC
  • Print_ISBN
    0-7803-4376-X
  • Type

    conf

  • DOI
    10.1109/PAC.1997.753171
  • Filename
    753171