Title :
Magnetic field strength and shape measurements of the Fermilab Main Injector quadrupoles
Author :
Harding, D.J. ; Brown, B.C. ; DiMarco, J. ; Glass, H.D. ; Kroc, T.K. ; Martin, P.S. ; Mishra, C.S. ; Walbridge, D.G.C. ; Pewitt, E.G.
Author_Institution :
Fermi Nat. Accel. Lab., Batavia, IL, USA
Abstract :
All of the new quadrupoles for the Fermilab Main Injector ring have been built and measured. The magnets are 2.95 m and 2.54 m in length with a 41.7 mm bore. In operation, the magnets run from 1.61 T/m at 8.9 GeV/c to 15.7 T/m at 120 GeV/c and 19.6 T/m at 150 GeV/c. These points correspond to injection, Main Injector fixed target physics and antiproton production, and extraction for transfer to the Tevatron. Good field uniformity is required to ensure a stable beam over the whole acceleration cycle. A significant octupole is included to assist in resonant extraction. The performance of these quadrupoles, in both integrated strength and field uniformity, is presented. All magnets produced meet the accelerator requirements
Keywords :
accelerator magnets; magnetic field measurement; particle beam injection; proton accelerators; storage rings; 2.54 m; 2.95 m; Fermilab Main Injector; antiproton production; field uniformity; integrated strength; magnetic field shape measurement; magnetic field strength measurement; octupole; quadrupoles; resonant extraction; Accelerator magnets; Apertures; Boring; Glass; Magnetic field measurement; Magnetic resonance; Magnetic separation; Proton accelerators; Rotation measurement; Shape measurement;
Conference_Titel :
Particle Accelerator Conference, 1997. Proceedings of the 1997
Conference_Location :
Vancouver, BC
Print_ISBN :
0-7803-4376-X
DOI :
10.1109/PAC.1997.753177