• DocumentCode
    2657640
  • Title

    IEN-CsF1 accuracy evaluation and two way frequency comparison

  • Author

    Levi, F. ; Lorini, L. ; Calonico, D. ; Bertacco, E.K. ; Godone, A.

  • Author_Institution
    Ist. Elettrotecnico Nazionale "G. Ferraris", Torino, Italy
  • fYear
    2003
  • fDate
    4-8 May 2003
  • Firstpage
    199
  • Lastpage
    204
  • Abstract
    In this paper we report the accuracy evaluation of the Italian primary frequency standard IEN-CsF1. We discuss the frequency shifts our frequency standard is corrected for and the procedure used for accuracy evaluation. In the last section we report a frequency comparison against two remote laboratory, the National Institute of Standard and Technology and the Physikalisch-Technische Bundesanstalt using the two way comparison technique.
  • Keywords
    atomic clocks; caesium; frequency stability; frequency standards; laboratories; Cs; Italian primary frequency standard IEN-CsF1; National Institute of Standard and Technology; Physikalisch-Technische Bundesanstalt; accuracy evaluation; frequency comparison; frequency shift; frequency standard; remote laboratory; Atomic beams; Atomic measurements; Clocks; Electron tubes; Frequency measurement; Laser beams; Laser modes; Masers; Measurement standards; Time measurement;