Abstract
Internal active parallel DC correctors in simple rectifiers help meeting the standard IEC 1000-3-2. As an example, a buck converter in parallel with a flyback DC corrector is considered. The principle of operation is experimentally verified. Idealized waveforms are analysed to establish the limits of the line voltage and processed power
Keywords
DC-DC power convertors; power factor correction; rectifying circuits; standards; IEC 1000-3-2; buck converter; flyback DC corrector; idealized waveforms; internal active parallel DC correctors; line voltage limits; line-current correctors; power-factor correctors; processed power limits; rectifiers; Circuits; Costs; DC-DC power converters; Harmonic distortion; IEC standards; Reactive power; Rectifiers; Surges; Topology; Voltage;