DocumentCode :
2657969
Title :
Failure statistics of DESY power supplies in 1996
Author :
Eckoldt, Hans-Joerg
Author_Institution :
DESY, Hamburg, Germany
Volume :
3
fYear :
1997
fDate :
12-16 May 1997
Firstpage :
3458
Abstract :
The HERA machine delivered good results in 1996. This was possible due to a higher availability of the technical subsystems than in the years before. Here the failures of the power supplies during 1996 will be analysed and a statistic of the failures of the accelerators will be shown. This will be compared to the failures of the last few years to see what improvements had the most success. A preview onto the next changes will be given and the introduction of new tools (software and hardware) will be explained
Keywords :
electron accelerators; power supplies to apparatus; power system faults; storage rings; DESY power supplies; HERA machine; accelerators; electron storage rings; failure statistics; Availability; Books; Electrons; Failure analysis; Hardware; Linear particle accelerator; Power supplies; Software tools; Statistical analysis; Statistics;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1997. Proceedings of the 1997
Conference_Location :
Vancouver, BC
Print_ISBN :
0-7803-4376-X
Type :
conf
DOI :
10.1109/PAC.1997.753241
Filename :
753241
Link To Document :
بازگشت