Title :
Magnetic measurements on an in-vacuum undulator for the NSLS X-ray ring
Author :
Rakowsky, G. ; Aspenleiter, J.J. ; Graves, W.S. ; Solomon, L. ; Stefan, P.M.
Author_Institution :
Nat. Synchrotron Light Source, Brookhaven Nat. Lab., Upton, NY, USA
Abstract :
Magnetic measurements have been performed on the In-Vacuum Undulator (IVUN), built jointly by BNL and SPring-8 for the NSLS X-ray Ring. The IVUN magnet has a Halbach-type, pure-permanent magnet structure with a period of 11 mm and a minimum gap of 2 mm. Results of magnetic measurements utilizing Hall probe, moving wire and pulsed wire techniques are presented and compared
Keywords :
electron accelerators; magnetic field measurement; permanent magnets; storage rings; wigglers; Halbach-type pure-permanent magnet structure; Hall probe; NSLS X-ray ring; in-vacuum undulator; magnetic measurements; moving wire; pulsed wire techniques; Apertures; Assembly; Bellows; Hall effect devices; Magnetic devices; Magnetic variables measurement; Performance evaluation; Tensile stress; Undulators; Wire;
Conference_Titel :
Particle Accelerator Conference, 1997. Proceedings of the 1997
Conference_Location :
Vancouver, BC
Print_ISBN :
0-7803-4376-X
DOI :
10.1109/PAC.1997.753254