DocumentCode
2658711
Title
Stress rupture considerations in the design of large aperture, low mass composite vacuum windows
Author
Leonhardt, W.J. ; Cullen, J.R. ; Gill, P.F.
Author_Institution
Brookhaven Nat. Lab., Upton, NY, USA
Volume
3
fYear
1997
fDate
12-16 May 1997
Firstpage
3583
Abstract
Large vacuum vessels are often employed in high energy and nuclear physics experiments to provide a volume for particle traverse in the absence of air molecules. The ends of these vessels generally have a large aperture which is closed with a thin membrane known as a vacuum window. To minimize the vacuum window mass, composites of Kevlar and Mylar have been used in window construction. Historically, these windows have been designed based on the ultimate tensile strength of the materials, however, following the costly failure of a 193 cm×86 cm window, other design methods emerged. This paper reviews the history of window design and describes the window failure and possible causes. It further presents the phenomenon of stress rupture and describes the analytical and experimental work carried out to improve composite window design methods
Keywords
composite materials; failure (mechanical); fracture; membranes; proton accelerators; synchrotrons; tensile strength; vacuum apparatus; 193 cm; 86 cm; AGS; Alternating Gradient Synchrotron; Kevlar-Mylar composites; large aperture vacuum windows; low mass composite vacuum windows; stress rupture; tensile strength; thin membrane; vacuum vessels; window failure; Apertures; Biomembranes; Design methodology; Elementary particle vacuum; Failure analysis; Geometry; Laboratories; Nuclear physics; Stress; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1997. Proceedings of the 1997
Conference_Location
Vancouver, BC
Print_ISBN
0-7803-4376-X
Type
conf
DOI
10.1109/PAC.1997.753281
Filename
753281
Link To Document