Abstract
The existing IEC standard prescribes humidity correction method of disruptive discharge voltage of standard sphere gaps, which is derived from experimental data under absolute humidity between 5 g/m3 and 12 g/m3. However, higher humidity is experienced in summer in Japan and also all over a year in tropical countries. In the present study, validity of the existing correction method is discussed for application up to 22 g/m3 based on a series of experiments for several years under natural humidity condition.
Keywords
IEC standards; air gaps; atmospheric humidity; discharges (electric); IEC standard; absolute humidity; disruptive discharge voltage; humidity correction; natural humidity condition; standard sphere air gap; Atmospheric measurements; Discharges; Humidity; IEC standards; Lightning; Temperature measurement; Voltage measurement;