• DocumentCode
    2658965
  • Title

    Investigations on the langasite resonators by X-ray topography

  • Author

    Mateescu, Irina ; Capelle, Bernard ; Detaint, Jacques ; Johnson, Gary ; Dumitrache, Liviu ; Bran, Cristina

  • Author_Institution
    Nat. Inst. of Mater. Phys., Bucharest, Romania
  • fYear
    2003
  • fDate
    4-8 May 2003
  • Firstpage
    637
  • Lastpage
    641
  • Abstract
    In this paper the results of electrical measurements of the mass-loading influence on Y-cut langasite resonator parameters are compared with those obtained by X-ray topography analysis of the same resonators. Based on the Ballato´s transmission-line analogs of the trapped-energy resonators vibrating in thickness-shear mode, the mass-loading effect on resonator characteristics was studied. The effective mass-loading, motional inductance and quality factor of langasite resonators were computed. Sawyer plan-parallel polished Y-cut langasite resonators with 14 mm diameter, 5 MHz resonant frequency, Au electrodes of 7 mm diameters and various thickness were used in experiments. X-ray topography measurements were performed by conventional transmission Laue setting using the white beam synchrotron radiation on fundamental, third and fifth overtones. The results are in agreement with those obtained by electrical measurements. The comparison of X-ray diffraction topography images previously performed on AT-cut quartz resonators with X-ray topographs on langasite resonators pointed out that the Y-cut langasite resonators are less influenced by the mass-loading than the AT-cut quartz resonators.
  • Keywords
    Q-factor; X-ray diffraction; X-ray topography; crystal resonators; gallium compounds; lanthanum compounds; 14 mm; 5 MHz; 7 mm; Au electrode; Ballato transmission line; La3Ga5SiO14; Laue transmission line; electrical measurement; langasite resonator; mass-loading effect; motional inductance; quality factor; quartz resonator; resonant frequency; shear mode vibration; trapped energy resonator; white beam synchrotron radiation; x-ray diffraction topography; Electric variables measurement; Electrodes; Gold; Inductance; Performance evaluation; Q factor; Resonant frequency; Surfaces; Transmission lines; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Frequency Control Symposium and PDA Exhibition Jointly with the 17th European Frequency and Time Forum, 2003. Proceedings of the 2003 IEEE International
  • ISSN
    1075-6787
  • Print_ISBN
    0-7803-7688-9
  • Type

    conf

  • DOI
    10.1109/FREQ.2003.1275165
  • Filename
    1275165