• DocumentCode
    2660041
  • Title

    Reliability of commercial relays during life tests with intermediate or low power contact load

  • Author

    Rieder, Wemer ; Strof, Thomas

  • Author_Institution
    Dept. of Switching Devices & High Voltage Technol., Tech. Univ. of Vienna, Austria
  • fYear
    1991
  • fDate
    6-9 Oct. 1991
  • Firstpage
    102
  • Lastpage
    108
  • Abstract
    The influence of the electrical stress on the contact resistance behavior of several signal and power relays has been investigated during life tests comprising 2 million operations. The results obtained with the aid of a specially developed test device showed characteristic contact resistance patterns for different electrical loads, contact materials, and designs. Under certain load conditions the contact resistance is increased by carbon deposits while both lower and higher loads caused lower contact resistance values.<>
  • Keywords
    contact resistance; life testing; relays; reliability; carbon deposits; contact load; contact resistance behavior; contact resistance patterns; electrical loads; electrical stress; life tests; load conditions; power relays; relays; reliability; Automatic testing; Circuit testing; Contact resistance; Electrical resistance measurement; Life testing; Materials testing; Modems; Pollution measurement; Relays; Switches;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Contacts, 1991. Proceedings of the Thirty-Seventh IEEE Holm Conference on
  • Conference_Location
    Chicago, IL, USA
  • Print_ISBN
    0-7803-0231-1
  • Type

    conf

  • DOI
    10.1109/HOLM.1991.170809
  • Filename
    170809