  • Abstract
    The ultra-high vacuum system of the PLS electron storage ring was successfully commissioned in July 1995. Since then, it routinely provides a dynamic pressure of about 7×10-10 Torr. The measured beam lifetime is more than 10 hours with 100 mA beam at 2 GeV. The rapid recovery of normal operation after installation of new components is achieved without in-situ bakeout by using a dry venting system. We present operation experiences with the NEG pumps and the performance of the vacuum system
  • Keywords
    electron accelerators; getters; storage rings; 0.0000000007 torr; 100 mA; 2 GeV; NEG pumps; PLS electron storage ring; PLS vacuum system; dry venting system; dynamic pressure; operation experiences; ultra-high vacuum system; Electron accelerators; Electron beams; Laboratories; Light scattering; Light sources; Particle scattering; Pumps; Storage rings; Strontium; Vacuum systems;