DocumentCode
2660258
Title
Numerical simulation of bioluminescence tomography
Author
Wei, Gong ; Ruo, Li ; Ningning, Yan ; Weibo, Zhao
Author_Institution
Acad. of Math. & Syst. Sci., Chinese Acad. of Sci., Beijing
fYear
2008
fDate
16-18 July 2008
Firstpage
585
Lastpage
588
Abstract
In this paper, an ill-posed problem is considered, which results from the area of molecular imaging and known as BLT problem. Using Tikhonov regularization technique, a quadratic optimization problem is formulated. We present a numerical simulation of the problem, and some numerical examples are presented.
Keywords
bioluminescence; medical image processing; numerical analysis; optical tomography; quadratic programming; Tikhonov regularization technique; bioluminescence tomography; ill-posed problem; molecular imaging; numerical simulation; quadratic optimization problem; Bioluminescence; Biomedical imaging; Boundary conditions; Mathematical model; Mathematics; Molecular imaging; Numerical simulation; Optical imaging; Optimal control; Tomography; BLT problem; Numerical simulation; Optimal control;
fLanguage
English
Publisher
ieee
Conference_Titel
Control Conference, 2008. CCC 2008. 27th Chinese
Conference_Location
Kunming
Print_ISBN
978-7-900719-70-6
Electronic_ISBN
978-7-900719-70-6
Type
conf
DOI
10.1109/CHICC.2008.4605159
Filename
4605159
Link To Document