• DocumentCode
    2666224
  • Title

    Effect of Peak Current Mode Control on Transient Response for VRM Application

  • Author

    Abe, Seiya ; Ninomiya, Tamotsu

  • Author_Institution
    Kyushu Univ., Fukuoka
  • Volume
    3
  • fYear
    2006
  • fDate
    14-16 Aug. 2006
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    The dynamics is improved to approximately first order by using peak current mode control, because of reducing a system order due to the inductor current is restrained as a control signal. However, the voltage mode control is mainly used, and there are few applications for which peak current mode control is used in VRM application. This paper presents, the transient response of VRM with peak current mode control is examined analytically and experimentally
  • Keywords
    electric current control; transient response; voltage control; voltage regulators; VRM application; inductor current; peak current mode control; transient response; Breakdown voltage; Buck converters; Capacitors; Control systems; Frequency modulation; Inductors; Power supplies; Transfer functions; Transient response; Voltage control; component; peak current mode control; transient response; voltage mode control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Motion Control Conference, 2006. IPEMC 2006. CES/IEEE 5th International
  • Conference_Location
    Shanghai
  • Print_ISBN
    1-4244-0448-7
  • Type

    conf

  • DOI
    10.1109/IPEMC.2006.4778279
  • Filename
    4778279