DocumentCode
2668032
Title
Iron Losses Under Voltage Excitation by Novel and Classical Frequency Converters
Author
Sagarduy, Juan ; Moses, Anthony J. ; Anayi, Fatih J. ; Clare, Jon ; Wheeler, Patrick W.
Author_Institution
Wolfson Centre for Magnetics, Cardiff University, United Kingdom
fYear
2006
fDate
Aug. 30 2006-Sept. 1 2006
Firstpage
131
Lastpage
136
Abstract
Iron losses due to flux harmonics in stator cores of Pulse-Width-Modulation [PWM] back -to-back inverter-fed induction motors have a major effect on system efficiency. A new generation of direct ac-ac matrix converters offer important advantages over classical frequency converters such as absence of bulky and temperature sensitive dc-links and possible adjustment of power factor. The paper presents experimental results of magnetic losses in three non-oriented electrical steels magnetised under different types of voltage excitation. Characteristic waveforms of real 3Ã3 matrix converter and PWM inverter under various modulation indices were recorded and used by a signal generator feeding a Single Strip Tester [SST] used to measure iron loss. Harmonic distortion, contribution of high frequency components and sideband effect were analysed. Influence of flux density curve as well as form factor of voltage excitation were also investigated.
Keywords
Frequency conversion; Induction generators; Induction motors; Iron; Magnetic flux; Matrix converters; Pulse inverters; Pulse width modulation inverters; Stator cores; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics and Motion Control Conference, 2006. EPE-PEMC 2006. 12th International
Conference_Location
Portoroz
Print_ISBN
1-4244-0121-6
Type
conf
DOI
10.1109/EPEPEMC.2006.4778388
Filename
4778388
Link To Document