• DocumentCode
    2668475
  • Title

    Soft sensor for flow measurement: overshot regulator

  • Author

    Wendt, Carl ; Weyer, Erik ; Mareels, Iven

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Melbourne Univ., Parkville, Vic., Australia
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    471
  • Lastpage
    475
  • Abstract
    Flow data for an open channel collected at an overshot regulator under submerged and closed loop operating conditions has been modelled according to traditional static hydraulic equations, and the parameters estimated. The parameter estimation task is based on system identification techniques. Further simplifications in order to improve the performance of the identified equations have been suggested and evaluated on the data set. These simplified model structures have been found to be better performed
  • Keywords
    closed loop systems; flow control; flow measurement; hydraulic systems; parameter estimation; water supply; closed loop operating conditions; flow control; flow measurement; irrigation; open channel; overshot regulator; parameter estimation; soft sensor; static hydraulic equations; submerged gates; submerged operating conditions; system identification techniques; Australia; Equations; Fluid flow measurement; Gold; Irrigation; Parameter estimation; Regulators; Sensor phenomena and characterization; Sensor systems; System identification;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Information, Decision and Control, 1999. IDC 99. Proceedings. 1999
  • Conference_Location
    Adelaide, SA
  • Print_ISBN
    0-7803-5256-4
  • Type

    conf

  • DOI
    10.1109/IDC.1999.754202
  • Filename
    754202