• DocumentCode
    2670622
  • Title

    A Study of Improving the Power Factor of a Three-Phase Induction Motor Using a Static Switched Capacitor

  • Author

    Jimoh, Adisa A. ; Nicolae, Dan V.

  • Author_Institution
    Dept. of Electr. Eng., Tshwane Univ. of Technol., Pretoria North
  • fYear
    2006
  • fDate
    Aug. 30 2006-Sept. 1 2006
  • Firstpage
    1088
  • Lastpage
    1093
  • Abstract
    In this paper a static switched capacitor with an auxiliary three-phase stator winding, which is only magnetically coupled to the stator main winding, is explored for improving the starting and operating power factor of a three-phase induction motor. The scheme improves the power factor of the motor without compromising significantly on other performances. Important advantages of the scheme include preventing harmonics in the line current, and eliminating regeneration possibility as well as preventing high inrush currents at starting
  • Keywords
    harmonics suppression; induction motors; power capacitors; power factor; starting; auxiliary three-phase stator winding; harmonics prevention; magnetic coupling; power factor; starting; static switched capacitor; three-phase induction motor; Capacitors; Couplings; Induction machines; Induction motors; Machine windings; Magnetic switching; Reactive power; Stator windings; Surges; Switches; Induction motors; Power factor correction; Reactive compensation; Three-phase machines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Motion Control Conference, 2006. EPE-PEMC 2006. 12th International
  • Conference_Location
    Portoroz
  • Print_ISBN
    1-4244-0121-6
  • Type

    conf

  • DOI
    10.1109/EPEPEMC.2006.4778547
  • Filename
    4778547