Abstract :
This paper describes a novel and low-cost technique for detecting process-related interconnect faults in Multichip Modules (MCMs). This method is an alternative to existing test methods such as TDNA, electron beam, electrical module test (EMT) and capacitance techniques which are either expensive in terms of test equipment, are cumbersome due to the requirement of multiple probes, or provide poor fault coverage. The new technique applies a stimulus through a resonator and a single ended probe at one end of the interconnect. By measuring the attenuation of the test stimulus due to pole movement relative to known attenuation measurements, interconnect faults such as latent opens, latent shorts, opens, and shorts can be detected
Keywords :
fault diagnosis; integrated circuit interconnections; integrated circuit packaging; multichip modules; probes; production testing; attenuation; fault coverage; latent opens; latent shorts; low-cost test technique; opens; process-related interconnect faults; shorts; single ended probe; test stimulus; unpopulated MCM substrate; Assembly; Circuit faults; Dielectric substrates; Electrical fault detection; Electron beams; Integrated circuit interconnections; Integrated circuit packaging; Probes; Semiconductor device packaging; System testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electronic Components and Technology Conference, 1996. Proceedings., 46th
Conference_Location :
Orlando, FL
ISSN :
0569-5503
Print_ISBN :
0-7803-3286-5
Type :
conf
DOI :
10.1109/ECTC.1996.517396
Filename :
517396
Link To Document :
بازگشت