DocumentCode :
2678972
Title :
Negative pressure wave-flow testing gas pipeline leak based on wavelet transform
Author :
Ma, Chunlong ; Yu, Shuhan ; Huo, Jinming
Author_Institution :
Inf. Eng. Dept., Chang Chun Univ., Jilin, China
Volume :
5
fYear :
2010
fDate :
24-26 Aug. 2010
Firstpage :
306
Lastpage :
308
Abstract :
To solve the problem of high false alarm rate and low positioning accuracy in the gas leak location detection, a new method is designed, in which wavelet transform is used to extract gas leak negative pressure wave signal, the gas leaks and positioning can be detected by using the method of negative pressure wave combined with flow balance. An algorithm of extracting negative pressure signal through wavelet transform is proposed and a method of negative pressure signal-flow rate detecting and positioning is provided. A negative pressure wave-flow testing gas pipeline leak system based on wavelet transform is designed. The positioning accuracy of the system reaches ± 1% of pipe length, and the false alarm rate is reduced.
Keywords :
leak detection; mechanical testing; natural gas technology; wavelet transforms; false alarm rate; gas leak location detection; gas leak negative pressure wave signal; negative pressure wave-flow testing gas pipeline leak system; positioning accuracy; wavelet transform; Monitoring; Transforms; flow; negative pressure wave; positioning; wavelet transform;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Computer, Mechatronics, Control and Electronic Engineering (CMCE), 2010 International Conference on
Conference_Location :
Changchun
Print_ISBN :
978-1-4244-7957-3
Type :
conf
DOI :
10.1109/CMCE.2010.5609975
Filename :
5609975
Link To Document :
بازگشت