DocumentCode
2679758
Title
Mercury-ion clock based on linear multi-pole ion trap
Author
Prestage, John D. ; Tjoelker, Robert L. ; Maleki, Lute
Author_Institution
Jet Propulsion Lab., California Inst. of Technol., Pasadena, CA, USA
fYear
2000
fDate
2000
Firstpage
706
Lastpage
710
Abstract
Buffer gas cooled clocks rely on large numbers of ions, typically ~107, optically pumped by a discharge lamp at scattering rates of a few photons per second per ion. To reduce the second-order Doppler shift from space charge repulsion of ions from the trap node line, novel multi-pole ion traps are now being developed where ions are weakly bound with confining fields that are effectively zero through the trap interior and grow rapidly near the trap electrode walls
Keywords
Boltzmann equation; Doppler shift; atomic clocks; frequency standards; mercury (metal); optical pumping; space charge; trapped ions; Boltzmann equation; Hg; Rabi pulse; buffer gas cooled clocks; effectively zero confining fields; ion cloud temperature; linear multipole ion trap; mercury-ion clock; second-order Doppler shift reduction; space charge repulsion of ions; trap electrode walls; trap node line; weakly bound ions; Clocks; Doppler shift; Electrodes; Lamps; Optical buffering; Optical pumping; Optical scattering; Particle beam optics; Particle scattering; Space charge;
fLanguage
English
Publisher
ieee
Conference_Titel
Frequency Control Symposium and Exhibition, 2000. Proceedings of the 2000 IEEE/EIA International
Conference_Location
Kansas City, MO
ISSN
1075-6787
Print_ISBN
0-7803-5838-4
Type
conf
DOI
10.1109/FREQ.2000.887441
Filename
887441
Link To Document