• DocumentCode
    2681167
  • Title

    Measurement of current taken by fluorescent lights in the frequency range 2-150 kHz

  • Author

    Larsson, E.O.A. ; Lundmark, C.M. ; Bollen, M.H.J.

  • Author_Institution
    Lulea Univ. of Technol.
  • fYear
    0
  • fDate
    0-0 0
  • Abstract
    This paper discusses measurements taken on fluorescent lights in the frequency range between 2 and 150 kHz. The presentation of the measurement results form an important part of the paper. The measurement results are presented in time-domain, in the frequency domain and in the time-frequency domain (by means of a "spectrogram"). The latter allows the study of sub-cycle changes in the current spectrum. The current taken by one lamp is compared with the current taken by two, three and four lamps. The relative high-frequency distortion reduced for frequencies above 15 kHz
  • Keywords
    electric current measurement; fluorescent lamps; time-frequency analysis; 2 to 150 kHz; current measurement; fluorescent lights; high-frequency distortion; time-frequency domain; Current measurement; Electromagnetic compatibility; Electronic ballasts; Fluorescence; Fluorescent lamps; Frequency measurement; Power harmonic filters; Power system harmonics; Time domain analysis; Voltage; Electromagnetic compatibility (EMC); Power quality; Short-time Fourier transform; energy-efficient lighting;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Engineering Society General Meeting, 2006. IEEE
  • Conference_Location
    Montreal, Que.
  • Print_ISBN
    1-4244-0493-2
  • Type

    conf

  • DOI
    10.1109/PES.2006.1709417
  • Filename
    1709417