DocumentCode :
2681798
Title :
Compact Dual Polarization Feeding System of HY-2 Calibration Radiometer
Author :
Hongjian, Wang ; Bin, Fan
Author_Institution :
Nat. Microwave Remote Sensing Lab., CSSAR, Beijing
Volume :
2
fYear :
2008
fDate :
7-11 July 2008
Abstract :
A new double-septums in main wave guide and single septum in side waveguide ortho-mode transducer (OMT) is proposed in this paper. Finite difference method in time domain (FDTD) and genetic algorithms (GAs) are combined to analysis and optimize this new OMT. The simulation results of the OMT together with the feed horn validate the better characteristics of the new OMT than that of the common structure. The VSWR of this OMT is less than 1.1 in the bandwidth, the cross-polar level of the feed can reach -25 dB, while the length of the main waveguide can be reduced at least 30%. On the other hand, in order to reduce the weight and length of the feed, a compact conical corrugated horn is also employed.
Keywords :
antenna feeds; calibration; electromagnetic wave polarisation; finite difference time-domain analysis; genetic algorithms; horn antennas; radiometers; radiometry; remote sensing; transducers; HY-2 calibration radiometer; compact dual polarization feeding system; conical corrugated horn; feed horn; finite difference time domain method; genetic algorithms; microwave remote sensing; side waveguide ortho-mode transducer; Algorithm design and analysis; Calibration; Feeds; Finite difference methods; Genetic algorithms; Optimization methods; Polarization; Radiometry; Time domain analysis; Transducers; FDTD; GA; OMT; conical corrugated horn; microwave remote sensing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Geoscience and Remote Sensing Symposium, 2008. IGARSS 2008. IEEE International
Conference_Location :
Boston, MA
Print_ISBN :
978-1-4244-2807-6
Electronic_ISBN :
978-1-4244-2808-3
Type :
conf
DOI :
10.1109/IGARSS.2008.4779211
Filename :
4779211
Link To Document :
بازگشت