DocumentCode :
2682695
Title :
Selective detection of water trees in cables
Author :
Jung, Jochen ; Patsch, Rainer
Author_Institution :
Inst. of Mater. & Diagnostics in Electr. Eng., Siegen Univ., Germany
fYear :
2000
fDate :
2000
Firstpage :
53
Lastpage :
56
Abstract :
The detection of water tree degradation in polymer insulated cables is still a serious problem for utilities. Most of the methods used in the field are able to detect severely degradated cables, in part because often a breakdown occurs during the test procedure itself. Unfortunately often the results do not allow to distinguish between early or intermediate stages of water tree degradation and some of the new cables with copolymer insulating materials show even `worse´ diagnostic parameter values than old water treed cables. In contrast to these methods the temperature dependence of loss tangent and capacitance is a very significant parameter, that is characteristic for water trees. The paper will deal with measurements of new and field aged cable specimens with and without additional ageing in the laboratory
Keywords :
ageing; capacitance measurement; dielectric loss measurement; insulation testing; organic insulating materials; power cable insulation; power cable testing; trees (electrical); ageing; capacitance; copolymer insulating material; dielectric breakdown; loss tangent; polymer insulation diagnosis; power cable; temperature dependence; water tree detection;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Dielectric Materials, Measurements and Applications, 2000. Eighth International Conference on (IEE Conf. Publ. No. 473)
Conference_Location :
Edinburgh
Print_ISBN :
0-85296-730-6
Type :
conf
DOI :
10.1049/cp:20000476