• DocumentCode
    2682892
  • Title

    Fast Determination of Active Components in Scutellaria Extract by NIRS Combined with PLS

  • Author

    Bai, Yan ; Zhang, Wei ; Xie, Cai-xia ; Wang, Xing ; Chen, Zhi-hong ; Gong, Hai-yan

  • Author_Institution
    Pharm. Coll., Henan Univ. of Traditional Chinese Med., Zhengzhou, China
  • fYear
    2012
  • fDate
    28-30 May 2012
  • Firstpage
    1034
  • Lastpage
    1037
  • Abstract
    In this paper, the three active components in Scutellaria Extract were rapidly determinate by near-infrared reflectance spectroscopy (NIRS). 100 samples of Scutellaria Extract from 12 different pharmaceutical factories were divided into a calibration set (80 samples) and a validation set (20 samples). In combination with the practical least square (PLS), the quantitative calibration models were established, involving baicalin, baicalein and wogonin. The correlation coefficient of cross-validation (R2cv) was 0.99481, 0.99867 and 0.99484 for baicalin, baicalein and wogonin, the root-mean-square error of calibration (RMSEC) was 0.440, 0.0225 and 0.0111, the root-mean-square error of cross-validation (RMSECV) was 2.259, 0.0553 and 0.0483. The validation samples were used to evaluate the performance of the models, the correlation coefficient of prediction (r2) was 0.9882, 0.9965 and 0.9909, the root-mean-square error of prediction (RMSEP) was 0.486, 0.0271 and 0.0110. The results indicated that NIRS can provide a simple and accurate way in the determination of the baicalin, baicalein and wogonin content in Scutellaria Extract.
  • Keywords
    biological techniques; calibration; correlation methods; infrared spectra; least mean squares methods; least squares approximations; medicine; molecular biophysics; organic compounds; pharmaceuticals; reflectivity; Scutellaria extract; baicalein; baicalin; calibration set; cross-validation correlation coefficient; near-infrared reflectance spectroscopy; partical least square; pharmaceutical factories; quantitative calibration models; root-mean square error; validation set; wogonin; Calibration; Correlation; Load modeling; Predictive models; Reflectivity; Spectral analysis; Spectroscopy; near-infrared reflectance spectroscopy; partical least square; quantitative calibration model; scutellaria extract;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Biomedical Engineering and Biotechnology (iCBEB), 2012 International Conference on
  • Conference_Location
    Macao
  • Print_ISBN
    978-1-4577-1987-5
  • Type

    conf

  • DOI
    10.1109/iCBEB.2012.223
  • Filename
    6245303