DocumentCode :
2683169
Title :
Accurate thermal impedance measurement for semiconductor lasers by the double modes of fiber grating lasers
Author :
Huang, S.Y.
Author_Institution :
AT&T Bell Labs., Breinigsville, PA, USA
fYear :
1996
fDate :
28-31 May 1996
Firstpage :
635
Lastpage :
639
Abstract :
The thermal impedance is an important parameter for a semiconductor laser, especially for a pump laser diode where a high current is needed to drive the laser to achieve the required performance. A precise measurement of thermal impedance is needed to characterize the thermal effect on the laser and to diagnose the thermal path on the laser packaging. Traditional measurements for the thermal impedance involve pulsing or modulating the lasers. Here, for the first time we used a complete optical method without electrical pulsation or modulation. The double mode spectra of fiber grating lasers were used to measure the thermal impedance of a semiconductor laser with accuracy not obtainable by other methods
Keywords :
fibre lasers; laser variables measurement; semiconductor lasers; double mode spectra; fiber grating laser; optical method; packaging; pump laser diode; semiconductor laser; thermal impedance measurement; thermal path; Diode lasers; Fiber lasers; Impedance measurement; Laser excitation; Laser modes; Optical modulation; Optical pumping; Pump lasers; Semiconductor device packaging; Semiconductor lasers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electronic Components and Technology Conference, 1996. Proceedings., 46th
Conference_Location :
Orlando, FL
ISSN :
0569-5503
Print_ISBN :
0-7803-3286-5
Type :
conf
DOI :
10.1109/ECTC.1996.517452
Filename :
517452
Link To Document :
بازگشت