Occurence and measurement of surface charges in the interrupter units of high-voltage circuit-breakers
Author
Zielke, E.
Author_Institution
Siemens AG, Germany
fYear
2000
fDate
2000
Firstpage
320
Lastpage
323
Abstract
All kinds of electrical plant and equipment incorporate parts made of insulating materials that can become electrically charged. It is actually undesirable for the equipment to pick up such charges because they can bring about a reduction in the dielectric strength of the material. This charging is well-known to occur in connection with the post insulators used in sulphur hexafluoride (SF6) gas-insulated switchgear. The intention in this report is to extend investigations to the insulating material parts incorporated in the interrupter units of SF6 high-voltage circuit-breakers
Keywords
SF6 insulation; charge measurement; circuit breakers; electric strength; gas insulated switchgear; insulation testing; interrupters; surface charging; SF6; SF6 high-voltage circuit-breakers; dielectric strength; high-voltage circuit-breakers; insulating materials; interrupter units; post insulators; sulphur hexafluoride gas-insulated switchgear; surface charges;