• DocumentCode
    2684837
  • Title

    High-efficiency interaction-free measurements using a stabilized Fabry-Perot cavity

  • Author

    Namekata, Naoto ; Inoue, Shuichiro

  • Author_Institution
    Inst. of Quantum Sci., Nihon Univ., Tokyo, Japan
  • Volume
    2
  • fYear
    2003
  • fDate
    15-19 Dec. 2003
  • Abstract
    Using a Fabry-Perot cavity with high transmittivity, it is possible to realize high-efficiency interaction-free measurements. In the scheme, it is required to stabilize the Fabry-Perot cavity when the measurements are performed. We have developed a stabilized Fabry-Perot cavity, and demonstrated the interaction-free measurements with the efficiency of 88 %.
  • Keywords
    Fabry-Perot interferometers; Fabry-Perot resonators; 88 percent; high-efficiency interaction-free measurements; stabilized Fabry-Perot cavity; transmittivity; Detectors; Diode lasers; Electrooptic modulators; Fabry-Perot; Laser beams; Object detection; Optical modulation; Particle measurements; Performance evaluation; Resonance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Lasers and Electro-Optics, 2003. CLEO/Pacific Rim 2003. The 5th Pacific Rim Conference on
  • Print_ISBN
    0-7803-7766-4
  • Type

    conf

  • DOI
    10.1109/CLEOPR.2003.1277238
  • Filename
    1277238