DocumentCode
2685129
Title
Analysis of PM synchronous motor drive failures during flux weakening operation
Author
Bianchi, N. ; Bolognani, S. ; Zigliotto, M.
Author_Institution
Dept. of Electr. Eng., Padova Univ., Italy
Volume
2
fYear
1996
fDate
23-27 Jun 1996
Firstpage
1542
Abstract
Under flux weakening operation, the phase emf of a PM synchronous motor can be extremely high; this paper investigates the effects on currents, voltages and torque of different drive failures occurring under flux weakening operation, as a starting point for a successful design of an effective system protection and a fault-tolerant control
Keywords
failure analysis; machine control; magnetic flux; permanent magnet motors; synchronous motor drives; synchronous motor protection; torque; PM synchronous motor drive failures; currents; failure analysis; fault-tolerant control; flux weakening operation; phase emf; system protection; torque; voltages; Brushless DC motors; Circuit faults; Control systems; DC motors; Failure analysis; Fault tolerance; Hysteresis motors; Permanent magnet motors; Pulse width modulation inverters; Synchronous motors;