DocumentCode
2685586
Title
Volumetric flow rate measurement with capacitive electromagnetic flowmeter in oil-water two-phase flow
Author
Wang, Baoliang ; Fu, Yongfeng ; Huang, Zhiyao ; Li, Haiqing
Author_Institution
Dept. of Control Sci. & Eng., Zhejiang Univ., Hangzhou, China
fYear
2010
fDate
3-6 May 2010
Firstpage
775
Lastpage
778
Abstract
A capacitive electromagnetic flowmeter working in voltage sensing mode is developed. The methods to keep noise to a minimum are described. The signal converter is designed to measure the signal from the sensor and get the flow rate. The prototype flowmeter is calibrated with water in a flow loop. After the calibration, the system is tested with oil-water two-phase flow. An electrode type electromagnetic flowmeter is also tested with oil-water two-phase flow. Test results show the capacitive electromagnetic flowmeter has better performance than the electrode type flowmeter for oil-water two-phase volumetric flow rate measurement.
Keywords
capacitive sensors; electromagnetic devices; flow measurement; flowmeters; two-phase flow; calibration; capacitive electromagnetic flowmeter; oil-water two-phase flow; prototype flowmeter; signal converter; voltage sensing mode; volumetric flow rate measurement; Capacitance; Capacitive sensors; Coils; Electrodes; Electromagnetic measurements; Fluid flow; Fluid flow measurement; System testing; Voltage; Volume measurement; capacitive electromagnetic flowmeter; oil-water twophase flow;
fLanguage
English
Publisher
ieee
Conference_Titel
Instrumentation and Measurement Technology Conference (I2MTC), 2010 IEEE
Conference_Location
Austin, TX
ISSN
1091-5281
Print_ISBN
978-1-4244-2832-8
Electronic_ISBN
1091-5281
Type
conf
DOI
10.1109/IMTC.2010.5488001
Filename
5488001
Link To Document