DocumentCode
2688482
Title
A direct reconstruction method of electromagnetic tomography(EMT) for high permeability and low conductivity distributions
Author
Cao, Zhang ; Xu, Lijun ; Wang, Huaxiang
Author_Institution
Sch. of Instrum. Sci. & Opto-Electron. Eng., Beihang Univ., Beijing, China
fYear
2010
fDate
3-6 May 2010
Firstpage
990
Lastpage
993
Abstract
A direct reconstruction method for electromagnetic tomography (EMT) is introduced. It is suitable to reconstruct the distributions with high permeability and low conductivity. By using the proposed method, the permeability distribution in any part of the region of interest can be obtained directly and independently. Simulated data for EMT with sixteen coils were obtained in two dimensions. Neither matrix inversion nor iteration was used in the process of image reconstruction. The reconstructed results validated the feasibility of the method.
Keywords
biomedical imaging; electrical conductivity; image reconstruction; magnetic permeability; matrix inversion; tomography; EMT; direct reconstruction method; electromagnetic tomography; high permeability distributions; image reconstruction; low conductivity distributions; matrix inversion; Coils; Conductivity; Differential equations; Eddy currents; Electrical capacitance tomography; Electromagnetic radiation; Image reconstruction; Laplace equations; Permeability; Reconstruction algorithms; direct reconstruction method; electromagnetic tomography; high-permeability; low-conductivity;
fLanguage
English
Publisher
ieee
Conference_Titel
Instrumentation and Measurement Technology Conference (I2MTC), 2010 IEEE
Conference_Location
Austin, TX
ISSN
1091-5281
Print_ISBN
978-1-4244-2832-8
Electronic_ISBN
1091-5281
Type
conf
DOI
10.1109/IMTC.2010.5488157