DocumentCode :
2688842
Title :
A fast, low cost method to check for moisture in epoxy molding compound
Author :
Lin, Jing ; Teng, Annette ; Yuen, Matthew M F
Author_Institution :
Dept. of Mech. Eng., Hong Kong Univ. of Sci. & Technol., Kowloon, Hong Kong
fYear :
1998
fDate :
8-10 Dec 1998
Firstpage :
359
Lastpage :
361
Abstract :
The absorption of moisture in epoxy molding compounds can be problematic for plastic packaging manufacturers, especially in East Asian countries and areas like Hong Kong, Singapore, and Malaysia, etc. The standard test method currently for testing suspect material is by Karl Fischer Titration. It is an electrochemical method, based on the reaction of iodine with water, which requires special equipment. In this study, we have applied differential scanning calorimetry (DSC) for moisture uptake testing of epoxy molding compounds. The epoxy molding compound sample is in uncured powder form or uncured pellet material. For epoxy molding compounds, there is an endothermic peak at the temperature around 40-50°C. This endothermic peak, which reflects the relaxation of uncured epoxy resin, is highly sensitive to moisture content. Samples were exposed to different conditions of relative humidity based on JEDEC standards, 30°C at 60% relative humidity for 24 hours and 48 hours, respectively. This work shows that a simple DSC can be used to check suspect material for moisture contamination. It is very important for manufacturers that the epoxy molding compound prior to processing must be kept in an acceptable place to avoid moisture absorption
Keywords :
chemical analysis; circuit reliability; dielectric relaxation; differential scanning calorimetry; encapsulation; environmental degradation; humidity; moisture; moulding; plastic packaging; polymers; standards; stress relaxation; 24 hr; 30 C; 40 to 50 C; 48 hr; DSC; JEDEC standards; differential scanning calorimetry; electrochemical method; endothermic peak; epoxy molding compound; epoxy molding compound preprocess storage; epoxy molding compounds; moisture; moisture absorption; moisture contamination; moisture content; moisture uptake testing; plastic packaging manufacture; relative humidity; standard test method; uncured epoxy resin relaxation; uncured pellet material sample; uncured powder sample; Absorption; Calorimetry; Costs; Humidity; Manufacturing; Materials testing; Moisture; Plastic packaging; Powders; Temperature sensors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electronics Packaging Technology Conference, 1998. Proceedings of 2nd
Print_ISBN :
0-7803-5141-X
Type :
conf
DOI :
10.1109/EPTC.1998.756030