DocumentCode :
2689667
Title :
Symmetric Test Fixture Calibration
Author :
Ehlers, E.R.
fYear :
1986
fDate :
2-4 June 1986
Firstpage :
275
Lastpage :
278
Abstract :
A symmetric test fixture can be calibrated for error-corrected measurements with two standards. Equations are presented for calibrating with either of two special sets of standards: 1) a thru of zero length and a matched load and 2) a thru of zero length and a matched 2-Port with unknown transmission characteristics. A measurement example is described for a fin-line test fixture.
Keywords :
Calibration; Equations; Fixtures; Measurement standards; Microwave measurements; Microwave technology; Millimeter wave measurements; Scattering parameters; Testing; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Symposium Digest, 1986 IEEE MTT-S International
Conference_Location :
Baltimore, MD, USA
ISSN :
0149-645X
Type :
conf
DOI :
10.1109/MWSYM.1986.1132168
Filename :
1132168