• DocumentCode
    2690865
  • Title

    On the issue of camera calibration with narrow angular field of view

  • Author

    Strobl, Klaus H. ; Sepp, Wolfgang ; Hirzinger, Gerd

  • Author_Institution
    Inst. of Robot. & Mechatron., German Aerosp. Center (DLR), Wessling, Germany
  • fYear
    2009
  • fDate
    10-15 Oct. 2009
  • Firstpage
    309
  • Lastpage
    315
  • Abstract
    This paper considers the issue of calibrating a camera with narrow angular field of view using standard, perspective methods in computer vision. In doing so, the significance of perspective distortion both for camera calibration and for pose estimation is revealed. Since narrow angular field of view cameras make it difficult to obtain rich images in terms of perspectivity, the accuracy of the calibration results is expectedly low. From this, we propose an alternative method that compensates for this loss by utilizing the pose readings of a robotic manipulator. It facilitates accurate pose estimation by nonlinear optimization, minimizing reprojection errors and errors in the manipulator transformations at the same time. Accurate pose estimation in turn enables accurate parametrization of a perspective camera.
  • Keywords
    cameras; manipulators; nonlinear control systems; pose estimation; camera calibration; computer vision; narrow angular field of view; nonlinear optimization; pose estimation; robotic manipulator; Calibration; Computer errors; Computer vision; Intelligent robots; Layout; Lenses; Manipulators; Nonlinear distortion; Robot vision systems; Smart cameras;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Intelligent Robots and Systems, 2009. IROS 2009. IEEE/RSJ International Conference on
  • Conference_Location
    St. Louis, MO
  • Print_ISBN
    978-1-4244-3803-7
  • Electronic_ISBN
    978-1-4244-3804-4
  • Type

    conf

  • DOI
    10.1109/IROS.2009.5354776
  • Filename
    5354776