DocumentCode :
2691086
Title :
Calibrating a Dual Six-Port or Four-Port for Measuring Two-Ports with Any Connectors
Author :
Hoer, C.A. ; Engen, G.F.
fYear :
1986
fDate :
2-4 June 1986
Firstpage :
665
Lastpage :
668
Abstract :
A technique is described for calibrating a dual six-port & four-port ANA so that the scattering parameters of two-port devices having any combination of connectors can be measured. The technique is a generalization of the "thru-reflect-line" (TRL) calibration technique in which the "thru" is replaced with a second length of precision transmission line.
Keywords :
Calibration; Connectors; Detectors; NIST; Power measurement; Power transmission lines; Reflection; Scattering parameters; Testing; Transmission line measurements;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Symposium Digest, 1986 IEEE MTT-S International
Conference_Location :
Baltimore, MD, USA
ISSN :
0149-645X
Type :
conf
DOI :
10.1109/MWSYM.1986.1132276
Filename :
1132276
Link To Document :
بازگشت