• DocumentCode
    2692221
  • Title

    Evaluation of adaptive perfusion models in dynamic contrast-enhanced ultrasound (DCE-US)

  • Author

    Fromageau, Jeremie ; Tunariu, Nina ; Bamber, Jeffrey C.

  • Author_Institution
    Joint Dept. of Phys., R. Marsden NHS Found. Trust, Sutton, UK
  • fYear
    2012
  • fDate
    7-10 Oct. 2012
  • Firstpage
    1311
  • Lastpage
    1314
  • Abstract
    Two new perfusions models of ultrasound contrast agents were derived from physiological considerations, and were compared to three published models to verify their reliability. All models were tested on a total of 43 clinical and preclinical data. The quality of the curve-fitting was estimated both by measuring the residuals and the correlation between the original data and the model. The result show that while most of the models fitted reliably the experimental data for long bolus injection, their fitting quality degrades significantly on replenishment data where less information was available. One of the newly proposed models was proved to keep a good quality of fitting in this situation which makes it a very good generic model.
  • Keywords
    biomedical ultrasonics; haemorheology; image enhancement; medical image processing; DCE-US; adaptive perfusion models; bolus injection; curve-fitting quality; dynamic contrast-enhanced ultrasound; generic model; preclinical data; ultrasound contrast agents; Adaptation models; Correlation; Data models; Fitting; Imaging; Mathematical model; Ultrasonic imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2012 IEEE International
  • Conference_Location
    Dresden
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4673-4561-3
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2012.0327
  • Filename
    6562279