Title :
Transient magnetic flux density measurement results on a fuselage-like test setup and investigation of the effects of apertures
Author :
Sebo, S.A. ; Caldecott, R. ; Altay, O. ; Schweickart, L. ; Horwath, J.C. ; Walko, L.C.
Author_Institution :
Dept. of Electr. Eng., Ohio State Univ., Columbus, OH, USA
Abstract :
Investigation of susceptibility of airborne equipment to high transient magnetic fields was conducted in a high current- and in a high voltage laboratory. Metal test cylinders were subjected to current impulses, up to 15 kA, simulating high surge currents, representing directed energy applications or lightning strokes. The cylinder used in the high current laboratory is made of aluminum and is representative in size and construction of an aircraft fuselage. Surge current measurements, dB/dt measurements outside and inside the test cylinders (B is the magnetic flux density), and the measured effects of apertures (open or closed) are described in the paper.
Keywords :
aircraft testing; aluminium; density measurement; electric current measurement; high-voltage techniques; lightning protection; magnetic flux; surges; aircraft fuselage; aluminum; current impulse; dB/dt measurements; fuselage-test setup; lightning strokes; surge current measurements; transient magnetic flux density measurement; Apertures; Current measurement; Density measurement; Laboratories; Magnetic field measurement; Magnetic flux density; Magnetic susceptibility; Surges; Testing; Voltage;
Conference_Titel :
Pulsed Power Conference, 2003. Digest of Technical Papers. PPC-2003. 14th IEEE International
Conference_Location :
Dallas, TX, USA
Print_ISBN :
0-7803-7915-2
DOI :
10.1109/PPC.2003.1277803