• DocumentCode
    2695454
  • Title

    Status of the Nevada shocker at the University of Nevada Las Vegas

  • Author

    Schill, Robert A., Jr. ; Culbreth, William ; Nielsen, Craig ; Popek, Marc ; Sipe, Nathan ; Blackstone, Brandon ; Goldfarb, Stan ; Fitzgerald, Walker ; Larson, Jason ; Walker, Mark ; Nosal, Scott ; Lull, Greg ; Viggato, Jason ; Raymond, Terry ; Subramanian

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Nevada Univ., Las Vegas, NV, USA
  • Volume
    2
  • fYear
    2003
  • fDate
    15-18 June 2003
  • Firstpage
    1229
  • Abstract
    The Nevada shocker is a 540 kV, 7 /spl Omega/, 50 ns pulsed power device based on Marx bank and Blumlein technologies. The Marx bank is composed of nine 60 kV capacitors charged in series with a gamma high voltage source connected by means of Ross relays in an air environment. A trigatron switch energized with an isolated mini capacitor bank is used to erect the Marx bank. The trigatron switch and erecting electrodes are contained in a gas manifold pressurized to 20 /spl plusmn/ 1 psi with dry air. The energy is released sequentially through an inductor and a water filled charging transmission line to the Blumlein immersed in deionized water. The Blumlein shapes and compresses the energy into a 50 ns pulse upon discharge. A self-breaking water switch initiates the release of energy in the Blumlein. The energy flows through a water filled discharging transmission line to the diode end of the Nevada Shocker. The current diode end of the Blumlein supports vacuum pressures as low as 6.5 /spl times/ 10/sup -6/ Torr. The chamber is pumped with the aid of a roughing pump and a cryogenic vacuum pump. The vacuum section of the Nevada Shocker is currently being rebuilt to incorporate mechanical and thermal loading capabilities with sensors located at the experiment. A number of diagnostic developments are currently underway to support flashover studies on plastics. Resistive probe and differential B-dot diagnostics with the aid of a 6 GHz 20 GS/s TDS 6604 real time scope is documented demonstrating the capability of the machine.
  • Keywords
    gas-discharge tubes; power capacitors; power inductors; pulsed power supplies; vacuum pumps; 540 kV; 6 GHz; 60 kV; 7 ohm; 90 kV; Blumlein technologies; Marx bank; Nevada shocker; Ross relays; TDS 6604 real time scope; University of Nevada Las Vegas; cryogenic vacuum pump; deionized water; gamma high voltage source; inductor; isolated mini capacitor bank; pulsed power device; trigatron switch; vacuum pressures; water filled charging transmission line; Capacitors; Diodes; Electrodes; Inductors; Isolation technology; Power transmission lines; Relays; Shape; Switches; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference, 2003. Digest of Technical Papers. PPC-2003. 14th IEEE International
  • Conference_Location
    Dallas, TX, USA
  • Print_ISBN
    0-7803-7915-2
  • Type

    conf

  • DOI
    10.1109/PPC.2003.1278035
  • Filename
    1278035