DocumentCode :
2695552
Title :
Battery life: do manufacturer and customer use the same language?
Author :
Kramm, Friedrich ; Sinz, Martin
Author_Institution :
Deutsche EXIDE GmbH, Budingen, Germany
fYear :
2004
fDate :
19-23 Sept. 2004
Firstpage :
309
Lastpage :
313
Abstract :
To close the gap of misunderstandings in terms of life and endurance definitions and expectations, a common data basis was worked out: Investigations of more than 2000 cells running in applications over the announced service life of more than 15 years. Investigation was carried out with stationary range OPzV/A600 in Gel-Technology produced 1982 to 1987 and investigated in the years 2003/2004. The result shows that all batteries have still more than 80% and a mean value of 97% of capacity, which was confirmed by the lab data. The lab test with float at room temperature and 40°C leads to service life of more than 16 years. Therefore no gap between the lab and field data could be observed in this case.
Keywords :
failure analysis; gels; lead acid batteries; life testing; reliability; Gel-Technology; OPzV/A600; Pb; battery life definition; endurance definition; lab test; service life; stationary range; Batteries; Lead; Life estimation; Life testing; Process design; Pulp manufacturing; Statistical analysis; Statistical distributions; Temperature; Uninterruptible power systems;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Telecommunications Energy Conference, 2004. INTELEC 2004. 26th Annual International
Print_ISBN :
0-7803-8458-X
Type :
conf
DOI :
10.1109/INTLEC.2004.1401484
Filename :
1401484
Link To Document :
بازگشت