• DocumentCode
    2696688
  • Title

    Spectral overlap considerations for simultaneous measurement of intracellular calcium concentration and transmembrane potentials in cardiac tissue

  • Author

    Johnson, Philip L. ; Knisley, Stephen B. ; Rollins, Dennis ; Smith, William M.

  • Author_Institution
    Dept. of Biomed. Eng., Alabama Univ., Birmingham, AL, USA
  • Volume
    6
  • fYear
    1997
  • fDate
    30 Oct-2 Nov 1997
  • Firstpage
    2367
  • Abstract
    Intracellular calcium concentration and transmembrane potentials are two important measurements used to study the mechanisms of cardiac activity. Fluorescent dyes have been used to measure these separately but not simultaneously in cardiac tissue. Fluo-3 has been used to measure intracellular calcium concentration and Di-4 ANEPPS has been used to measure membrane potentials in cardiac tissue. This paper addresses the feasibility of using these fluorescent dyes on the heart together and thereby measuring membrane potentials and intracellular calcium concentration simultaneously. In order for the dyes to be used simultaneously, it is necessary for their respective fluorescent spectra to be sufficiently separated in wavelength, thus allowing them to be separated by optical filters or spectrographs. An apparatus was constructed to measure the dyes´ spectra. The spectra obtained from this equipment were mathematically modeled in order to assess the spectral overlap error under different conditions. Error curves were constructed which may guide the researcher to pick optical filters and dye concentrations that will result in an acceptable error
  • Keywords
    bio-optics; biochemistry; bioelectric potentials; biological tissues; biomedical measurement; biomembrane transport; cardiology; dyes; fluorescence spectroscopy; Ca; Di-4 ANEPPS; Fluo-3; cardiac activity mechanisms; cardiac tissue; dye concentrations; fluorescent dyes; intracellular calcium concentration; optical filters; simultaneous measurement; spectral overlap considerations; spectral overlap error; transmembrane potentials; Biomedical measurements; Biomedical optical imaging; Biomembranes; Calcium; Cardiac tissue; Fluorescence; Optical arrays; Optical filters; Stimulated emission; Wavelength measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1997. Proceedings of the 19th Annual International Conference of the IEEE
  • Conference_Location
    Chicago, IL
  • ISSN
    1094-687X
  • Print_ISBN
    0-7803-4262-3
  • Type

    conf

  • DOI
    10.1109/IEMBS.1997.756793
  • Filename
    756793