DocumentCode
2698440
Title
Anechoic chamber related issues for very large automated planar near field range
Author
Christopher, S. ; Rao, Aruna ; Varughese, Suma ; Easwaran, M.S.
Author_Institution
Electron. & Radar Dev. Establ., Bangalore, India
fYear
1997
fDate
3-5 Dec 1997
Firstpage
75
Lastpage
82
Abstract
LRDE has set up an automated planar near field measurement facility with a size of 18 m×12 m×10 m. This paper discusses anechoic chamber related issues, such as the requirement of the absorbers, quiet zone etc. which were faced during the design stage. A novel technique to enhance the quiet zone with commercially available absorbers, with -40 to -50 dB reflectivity is explained
Keywords
anechoic chambers; antenna testing; electromagnetic interference; electromagnetic wave absorption; interference suppression; LRDE; absorbers; anechoic chamber; automated planar near field measurement facility; design; large automated planar near field range; quiet zone; reflectivity; Anechoic chambers; Antenna measurements; Communication system control; Control systems; Directive antennas; Electromagnetic interference; Electromagnetic measurements; Feeds; Programmable control; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Interference and Compatibility '97. Proceedings of the International Conference on
Conference_Location
Hyderabad
Print_ISBN
81-900652-0-3
Type
conf
DOI
10.1109/ICEMIC.1997.669770
Filename
669770
Link To Document