Abstract
This paper describes the application of electrical impedance tomography (EIT) to a plant scale mixing vessel. A cylindrical mixing tank with a diameter of 7 ft (2.13 m) has been equipped with a single plane of sensing electrodes. These sensors connect to a low-cost PC based data acquisition system, which uses a dual-opposing drive signal arrangement. Initial imaging of static discontinuities within the vessel are shown
Keywords
computerised monitoring; computerised tomography; data acquisition; electric impedance imaging; image reconstruction; mixing; process control; 7 ft; background signal compensation; cylindrical mixing tank; dual-opposing drive signal arrangement; electrical impedance tomography; independent source scaling; low-cost PC based data acquisition; plant scale mixing vessel; process tomography; single plane of sensing electrodes; static discontinuities imaging; vessel instrumentation;