Abstract :
This paper presents the technique for detection of shorted turns in stator winding of induction motors. The strategy is based on the dq0 voltage components. The proposed technique determines dq components of time domain of harmonics obtained from Park transformation instead of the stator phase voltage. Zero component (0) is calculated from the fundamental voltage excitation only. In the testing, the supply is sinusoidal waveform and the motor must be star connected with floating neutral. From experimental results, pattern of dq0 voltage components in order to use for the stator faults detection is possible.
Keywords :
fault diagnosis; harmonic analysis; induction motors; stators; time-domain analysis; Park transformation harmonics; fault detection; induction motor; sinusoidal waveform; star connection; stator winding; time domain analysis; Circuit faults; Electrical fault detection; Fault detection; Induction motors; Magnetic flux; Rotors; Saturation magnetization; Stator cores; Stator windings; Voltage; Induction motor; condition monitoring; dq0 components; fault detection; stator fault;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Technology, 2008. ICIT 2008. IEEE International Conference on
Conference_Location :
Chengdu
Print_ISBN :
978-1-4244-1705-6
Electronic_ISBN :
978-1-4244-1706-3
Type :
conf
DOI :
10.1109/ICIT.2008.4608400
Filename :
4608400
Link To Document :
بازگشت