DocumentCode :
2706517
Title :
Reliability of micromachined catalytic gas sensors
Author :
Norman, Aaron ; Stam, Frank ; Dücso, Csaba
Author_Institution :
Nat. Microelectron. Res. Centre, Univ. Coll. Cork, Ireland
Volume :
2
fYear :
2003
fDate :
22-24 Oct. 2003
Firstpage :
1310
Abstract :
This work reports on the reliability testing of micromachined hotplates designed for calorimetric gas sensors. The devices consist of a platinum resistive heater on a silicon nitride substrate under which polysilicon has been etched. The devices have proprietary catalysts deposited onto the surface prior to reliability testing. Environmental, mechanical and electrical tests were performed on the devices. IR thermography work is described to demonstrate device processing issues as observed during some reliability tests. In general devices showed good mechanical stability, but the catalytic material deposited on the sensors showed some problems.
Keywords :
catalysis; gas sensors; micromachining; Pt resistive heater; mechanical stability; micromachined catalytic gas sensors; micromachined hotplates; reliability testing; Electric shock; Gas detectors; Humidity; Intelligent sensors; Sensor arrays; Silicon; Temperature; Testing; User-generated content; Vibrations;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Sensors, 2003. Proceedings of IEEE
Print_ISBN :
0-7803-8133-5
Type :
conf
DOI :
10.1109/ICSENS.2003.1279158
Filename :
1279158