• DocumentCode
    2711337
  • Title

    DC-Link Voltage Pumping-up Analysis and Phase Shift Control for a Series Active Voltage Regulator

  • Author

    Guochun Xiao ; Zhiliang Hu ; Changhe Nan ; Zhaoan Wang

  • Author_Institution
    Sch. of Electr. Eng., Xi´an Jiaotong Univ.
  • fYear
    2006
  • fDate
    18-22 June 2006
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    The DC-link voltage pumping-up phenomenon is analyzed for a series active voltage regulator in the paper. In order to avoid DC-link voltage pumping-up, a phase shift compensation strategy is proposed, and the relationship between the source overvoltage ratio, load power factor, phase shift angle and compensation voltage provided by the inverter is presented in detail. Taking a series active voltage regulator used in low voltage distribution for example, the parameters aforementioned are calculated. A group practical design curves for suppressing DC-link voltage pumping-up with phase shift control algorithm are obtained. The effectiveness of this novel control strategy is also verified by some simulation results
  • Keywords
    invertors; phase shifters; power factor; voltage regulators; DC-link voltage pumping-up analysis; inverter compensation voltage; load power factor; overvoltage ratio; phase shift angle; phase shift compensation strategy; phase shift control algorithm; series active voltage regulator; Algorithm design and analysis; Coupling circuits; Low voltage; Power systems; Pulse width modulation inverters; Reactive power; Rectifiers; Regulators; Voltage control; Voltage fluctuations;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Specialists Conference, 2006. PESC '06. 37th IEEE
  • Conference_Location
    Jeju
  • ISSN
    0275-9306
  • Print_ISBN
    0-7803-9716-9
  • Type

    conf

  • DOI
    10.1109/PESC.2006.1711864
  • Filename
    1711864