• DocumentCode
    271175
  • Title

    Implementation of a high-voltage primary standard method using a capacitance bridge

  • Author

    Rodrigues de Lima, Vladimir ; Agazar, Mohamed ; Blanc, Isabelle ; Janin, Pierre Jean ; Cals de Oliveira Vitorio, Patrícia ; Abreu de Souza, Leonardo Augusto ; Wanner Ganvini, Otto

  • Author_Institution
    Inst. Nac. de Metrol. Qualidade e Tecnol. (Inmetro), Duque de Caxias, Brazil
  • fYear
    2014
  • fDate
    24-29 Aug. 2014
  • Firstpage
    616
  • Lastpage
    617
  • Abstract
    This paper presents a high voltage primary standard method using a current comparator bridge. A commercial capacitance bridge is used with two standard capacitors to determine the ratio error and phase displacement of a 10 kV and 30 kV reference voltage transformers. The bridge is calibrated in capacitance and dissipation factor and the standard capacitors are characterized in voltage and temperature. The measurements were carried out at LNE in a high voltage Faraday cage at power frequency (50 Hz) and for voltages going up to 120 % of the nominal voltages of the reference voltage transformers. An expanded uncertainty of 25 parts in 10-6 was estimated for the ratio error and 17 μrad for the phase displacement. In addition it was found a good agreement with the last calibration results made in 1981 which used resistive divider in a passive bridge.
  • Keywords
    bridge circuits; calibration; capacitance measurement; capacitors; current comparators; displacement measurement; measurement standards; phase estimation; phase measurement; potential transformers; voltage measurement; LNE; calibration; capacitance bridge; capacitor; current comparator bridge; frequency 50 Hz; high voltage Faraday cage; high-voltage primary standard method; passive bridge; phase displacement; reference voltage transformer; resistive divider; voltage 10 kV; voltage 30 kV; Bridge circuits; Calibration; Capacitance; Capacitors; Standards; Voltage measurement; Voltage transformers; Voltage transformers; capacitance bridge; phase displacement; precision measurement; ratio error; traceability;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
  • Conference_Location
    Rio de Janeiro
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4799-5205-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2014.6898536
  • Filename
    6898536