• DocumentCode
    2712378
  • Title

    Transfer impedance measurement of a 19"-subrack

  • Author

    Bernauer, J. ; Schwab, A.J.

  • Author_Institution
    Inst. of Electr. Energy Syst. & High-Voltage Technol., Karlsruhe Univ., Germany
  • fYear
    1996
  • fDate
    19-23 Aug 1996
  • Firstpage
    360
  • Lastpage
    365
  • Abstract
    The transfer impedance of a 19"-aluminum subrack has been measured by injecting a current into the shield surface and measuring the voltage across the inner surface between the injection points. The measurements were performed in the frequency range from dc up to 30 MHz. With two different set-ups, the influence of the current return path was examined. The surface transfer impedance depends strongly on the mounting conditions of the basic unit (side plates and horizontal rails) and the covers. The interference currents were symmetrically injected into opposite shield surfaces in x, y and z-direction
  • Keywords
    electric impedance measurement; electromagnetic interference; electromagnetic shielding; 0 Hz to 30 MHz; 19"-aluminum subrack; current return path; horizontal rails; interference currents; mounting conditions; opposite shield surfaces; shield surface; shielding enclosures; side plates; surface transfer impedance; transfer impedance measurement; voltage measurement; Coaxial components; Conducting materials; Eddy currents; Fasteners; Impedance measurement; Interference; Rails; Strips; Surface impedance; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 1996. Symposium Record. IEEE 1996 International Symposium on
  • Conference_Location
    Santa Clara, CA
  • Print_ISBN
    0-7803-3207-5
  • Type

    conf

  • DOI
    10.1109/ISEMC.1996.561258
  • Filename
    561258