DocumentCode
271259
Title
Using measurement of AC parameters for CIGS PV modules degradation studying
Author
CÌŒernaÌ, L. ; CÌŒernek, P. ; Hrzina, P. ; Benda, Vitezslav
Author_Institution
Dept. of Electrotechnol., Czech Tech. Univ. in Prague, Prague, Czech Republic
fYear
2014
fDate
12-14 May 2014
Firstpage
307
Lastpage
310
Abstract
There are many diagnostic methods for PV modules parameters determination used. Most of them are based on measurement of static parameters, but therefore exist also measurement methods for AC parameters such a capacitance or impedance determination. In the paper is described Time Domain Reflectometry method which can be used for differentiation of PV modules with same static plate values. Different AC parameters can cause dissimilar behavior in alternating fields leading to premature degradation.
Keywords
copper compounds; electric current measurement; gallium compounds; indium compounds; solar cells; time-domain reflectometry; AC parameter measurement method; CIGS PV module degradation; Cu(InGa)Se2; capacitance determination; impedance determination; static plate values; time domain reflectometry method; Current measurement; Degradation; Impedance; Inverters; Temperature measurement; Transmission line measurements; Voltage measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Microelectronics Proceedings - MIEL 2014, 2014 29th International Conference on
Conference_Location
Belgrade
Print_ISBN
978-1-4799-5295-3
Type
conf
DOI
10.1109/MIEL.2014.6842150
Filename
6842150
Link To Document