    Analysis and modification of a ZVT inverter behavior

  • Author

    Rahimi, Khalil ; Farzanehfard, Hosein

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Isfahan Univ. of Technol., Isfahan, Iran
  • Volume
    2
  • fYear
    2009
  • fDate
    4-6 Oct. 2009
  • Firstpage
    807
  • Lastpage
    812
  • Abstract
    A new soft-switching control scheme for the auxiliary resonant commutated pole (ARCP) ZVT inverter is proposed in this paper. In the proposed control circuit, only instantaneous voltage feedback of switches is used for triggering main switches to provide ZVS condition. In this method, the advantages of previous control strategy are kept while the need for current sensing is eliminated. Furthermore, the auxiliary switches current stress is reduced and thereby has decreased the conduction losses. The operating principle and design procedure are presented in this paper. Simulation results verify the validity of the proposed scheme.
  • Keywords
    invertors; switching convertors; zero voltage switching; ZVS; ZVT inverter; auxiliary resonant commutated pole; auxiliary switches current stress; soft-switching control scheme; voltage feedback; Circuits; Electric variables control; Inductors; Pulse width modulation inverters; Resonance; Switches; Timing; Topology; Voltage control; Zero voltage switching; Load side; Soft-switching; ZVT Inverter;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics & Applications, 2009. ISIEA 2009. IEEE Symposium on
  • Conference_Location
    Kuala Lumpur
  • Print_ISBN
    978-1-4244-4681-0
  • Electronic_ISBN
    978-1-4244-4683-4
  • Type

    conf

  • DOI
    10.1109/ISIEA.2009.5356333
  • Filename
    5356333