• DocumentCode
    2712702
  • Title

    A Control Method for Improvement of Reliability in Fault Tolerant NPC Inverter System

  • Author

    Jae-chul Lee ; Tae-Jin Kim ; Dae-Wook Kang ; Dong-Seok Hyun

  • Author_Institution
    Dept. of Electr. Eng., Hanyang Univ., Seoul
  • fYear
    2006
  • fDate
    18-22 June 2006
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    In this paper, a simple method for fault tolerance is proposed for improvement of reliability when the NPC inverter fault occurs in the switching device. The fault of switching device is detected by checking the change of a leg-voltage in NPC inverter. This method has some advantage of fast detection ability and a simple realization for fault detection, compared with conventional methods. Also, reconfiguration is performed by two phases control method which used to supply the balancing three phases voltage to the load continuously. This proposed method help the system minimize the harmful affection to the load caused by a delay of fault detection. The proposed method has been verified by simulation and experiment
  • Keywords
    fault tolerance; invertors; phase control; switching convertors; fault detection delay; fault tolerant NPC inverter system; switching device; two phase control method; Capacitors; Circuit faults; Control systems; Electrical fault detection; Fault detection; Fault tolerance; Fault tolerant systems; Power system reliability; Pulse width modulation inverters; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Specialists Conference, 2006. PESC '06. 37th IEEE
  • Conference_Location
    Jeju
  • ISSN
    0275-9306
  • Print_ISBN
    0-7803-9716-9
  • Type

    conf

  • DOI
    10.1109/PESC.2006.1711954
  • Filename
    1711954